Skip to main content

Poor signal or LOS

Symptom: unstable, slow, dropping connection — or the CPE is in LOS (loss of optical signal).

Quick diagnosis​

Poor signal / LOS
Open the CPE's Optics tab
CPE Rx?
No signal / LOSPhysical fiber problem → Technical visitBelow -27 dBmWeak signal - degradation → Technical visitBetween -8 and -25 dBmSignal OK - investigate another cause

Step by step​

  1. Open the CPE and go to the Optics tab. Click Sync to get the current value.

  2. Read the CPE Rx (power received by the ONU):

    • Between -8 and -25 dBm → healthy signal. The problem is probably not optical; go back to Customer with no connection and investigate WAN/WiFi.
    • -25 to -27 dBm → attention, starting to degrade.
    • Below -27 dBm → weak signal; high chance of instability.
    • No signal / LOS → total loss.
  3. Cross-check with the Events tab: many drops/reconnects confirm physical instability.

  4. Check whether the problem is isolated or collective: use the Signal Level Report filtering by the same OLT. If several customers on the same OLT/PON port are poor, the problem is in the provider's network (backbone/splitter), not at the customer's home.

Most common causes​

CauseIndicationAction
Broken fiberSudden LOSTechnical visit
Dirty/loose connectorVery low, fluctuating signalField cleaning/reconnection
Bend/kink in the customer's fiberWeak signal on only this customerFix the installation
Splitter/network problemSeveral customers on the same OLT poor at onceEscalate to engineering/NOC
Signal too strong (above -8 dBm)RX too strongField attenuation adjustment

When to escalate​

  • LOS or weak signal on one customer → technical visit.
  • Poor signal on several customers on the same OLT/port → engineering/NOC (infrastructure problem).