Skip to main content

Poor signal or LOS

Symptom: unstable, slow, dropping connection — or the CPE is in LOS (loss of optical signal).

Quick diagnosis

Poor signal / LOS
Open the CPE's Optics tab
CPE Rx?
No signal / LOSPhysical fiber problem → Technical visitBelow -27 dBmWeak signal - degradation → Technical visitBetween -8 and -25 dBmSignal OK - investigate another cause

Step by step

  1. Open the CPE and go to the Optics tab. Click Sync to get the current value.

  2. Read the CPE Rx (power received by the ONU):

    • Between -8 and -25 dBm → healthy signal. The problem is probably not optical; go back to Customer with no connection and investigate WAN/WiFi.
    • -25 to -27 dBm → attention, starting to degrade.
    • Below -27 dBm → weak signal; high chance of instability.
    • No signal / LOS → total loss.
  3. Cross-check with the Events tab: many drops/reconnects confirm physical instability.

  4. Check whether the problem is isolated or collective: use the Signal Level Report filtering by the same OLT. If several customers on the same OLT/PON port are poor, the problem is in the provider's network (backbone/splitter), not at the customer's home.

Most common causes

CauseIndicationAction
Broken fiberSudden LOSTechnical visit
Dirty/loose connectorVery low, fluctuating signalField cleaning/reconnection
Bend/kink in the customer's fiberWeak signal on only this customerFix the installation
Splitter/network problemSeveral customers on the same OLT poor at onceEscalate to engineering/NOC
Signal too strong (above -8 dBm)RX too strongField attenuation adjustment

When to escalate

  • LOS or weak signal on one customer → technical visit.
  • Poor signal on several customers on the same OLT/port → engineering/NOC (infrastructure problem).