Skip to main content

CPE with no power (Dying Gasp)

Symptom: the CPE shows up as No power.

What it means

When the ONU loses power, it sends the OLT one last alert called Dying Gasp. Cpehub interprets this alert and marks the device as No power — distinguishing it from a fiber drop (LOS) or a freeze (Offline).

In other words: No power = likely power outage at the customer's home. This is the easiest scenario, since it tends to resolve itself once power comes back.

Step by step

  1. Confirm the No power status on the CPE and the Dying Gasp event on the Events tab.

  2. Check whether it's isolated or collective:

    • Several CPEs without power in the same region/OLT at the same time → power outage in the area (utility company) or at the provider's own POP.
    • Just one customer → power outage at their home, faulty outlet/power adapter.
  3. Guide the customer to check the power, adapter, and cable of the device.

Most common causes

CauseIndicationAction
Power outage at homeOne customer, Dying GaspWait for power to come back / check outlet and adapter
Faulty power adapterCustomer recurrently without powerReplace the adapter
Power outage in the areaSeveral customers at onceWait for the utility company
Power outage at the POPMany CPEs from several OLTsEscalate urgently (NOC)

When to escalate

  • Many CPEs without power at the same time (POP/backbone) → NOC, urgent.
  • Customer's power is OK but the device won't turn on → equipment/adapter replacement.